Protective-glove RFQs still often say “ANSI cut A4,” “cut level 5,” or “ANSI/ISEA 105 certified” and stop there. That shorthand is too thin. ANSI/ISEA 105 is an American National Standard for classifying the performance of hand and arm protection. A cut level is a test classification. It is not a medical-glove rating, not a CE mark, and not a substitute for naming the actual job hazard.
The International Safety Equipment Association (ISEA) describes ANSI/ISEA 105-2024 as a classification system for hand and arm protection, including gloves and sleeves, based on performance criteria used in workplace PPE selection. The ANSI Blog’s public overview of the same edition gives the standard’s full title as ANSI/ISEA 105-2024: American National Standard For Hand Protection Classification.
This guide restates those public ISEA and ANSI pages at buyer level, explains how the A1–A9 cut scale is described there, and lists the questions that belong in an RFQ. It should be read together with EN 388 protective gloves when a tender names both a North American cut level and a European mechanical-risk code.
It does not claim that any JUNDA, Yue Long, Baijiebang, or other JUNDA protective or disposable line is ANSI/ISEA 105 classified, tested to ASTM F2992, or marked with a particular cut, abrasion, or puncture level. It is not legal, regulatory, or occupational-safety advice. Confirm requirements against the current standard text, the marking and user information supplied with the glove, destination PPE rules, and the files that belong to the exact SKU to be offered or shipped.
What ANSI/ISEA 105 is — and what it is not
ISEA’s public guide to the 2024 edition says ANSI/ISEA 105-2024 provides a classification system for hand and arm protection, including gloves and sleeves. It highlights three performance families:
- Mechanical protection — including cut, puncture, and abrasion resistance.
- Chemical protection — tests for permeation and degradation resistance.
- Heat and flame protection — including ignition resistance, heat degradation, and conductive heat resistance.
ISEA states that hand and arm protection shall be classified according to their resulting performance when tested in accordance with the specified test method. For cut resistance, ISEA’s public page names ASTM F2992-23 as the standardized test method used in this edition.
The ANSI Blog’s public overview adds a scope boundary that buyers often miss. ANSI/ISEA 105-2024 addresses classification and testing of hand and arm protection for specific performance properties related to chemical and industrial applications. Hand and arm protection includes gloves, mittens, partial gloves, sleeves, or other items covering the hand or a portion of the hand that are intended to provide protection against or resistance to a specific hazard. The same overview states that the standard does not address protection from electric shock, ionizing or non-ionizing radiation, every type of thermal exposure and harmful temperature extreme, or every type of exposure to chemicals, biological agents, or other hazardous substances. It also does not address protection for welding, emergency response, or firefighter applications.
What ANSI/ISEA 105 is not:
- It is not the European mechanical-risk standard. A North American cut class is not automatically an EN 388 letter. See EN 388 protective gloves.
- It is not the general-requirements standard used with European PPE gloves. Fit, innocuousness, sizing, marking and user information in that framework still sit with EN ISO 21420.
- It is not a medical-glove barrier standard. Single-use medical gloves follow a different conversation, such as EN 455 medical gloves.
- It is not, by itself, a CE mark, a UKCA mark, or an OSHA certificate.
- It is not a guarantee that a glove is cut-proof, or that every part of the glove has the same classification.
- It is not a certificate number you can invent from a catalogue.
ISEA also notes that following ANSI/ISEA 105-2024 is voluntary, while U.S. OSHA rules still require employers to address appropriate hand protection when employees’ hands are exposed to hazards, citing 29 CFR 1910.138(a) and 1910.138(b). That is a useful distinction for RFQs: a classification can inform selection. It does not turn a cut letter into legal advice, and it does not prove that a workplace has met OSHA requirements.
How public pages describe the A1–A9 cut scale
Cut resistance is the classification buyers quote most often—and the one most often copied out of context.
ISEA’s public fact sheet says cut resistance is classified by the weight needed to cut through the material with 20 mm of blade travel. ISEA’s public classification poster for ANSI/ISEA 105-2024 presents nine cut levels in grams-force (gf):
- A1 — 200 gf
- A2 — 500 gf
- A3 — 1,000 gf
- A4 — 1,500 gf
- A5 — 2,200 gf
- A6 — 3,000 gf
- A7 — 4,000 gf
- A8 — 5,000 gf
- A9 — 6,000 gf
The ANSI Blog’s public overview of the same edition presents these as bands: A1 200–499 g, A2 500–999 g, A3 1,000–1,499 g, A4 1,500–2,199 g, A5 2,200–2,999 g, A6 3,000–3,999 g, A7 4,000–4,999 g, A8 5,000–5,999 g, and A9 6,000 g and above.
Those public figures are a buyer-level orientation. They are not a substitute for the paid standard text, and they are not factory results for any JUNDA SKU. ISEA’s poster also groups example tasks next to cut levels; treat those examples as orientation, not as a rule that a named job must use a named level. The right class still depends on the actual hazard, the part of the glove being tested, and the destination’s own selection rules.
A higher cut class is not automatically the better buy. Dexterity, grip, coating, cuff, and other hazards (chemical, heat, puncture) can matter as much as the cut letter. The ANSI Blog notes that dexterity and anti-vibration are no longer specifically covered in the 2024 edition, though they may still appear in an appendix discussion of other factors.
The pentagon marking is not a completed offer
The 2024 edition introduced a standardized way to show selected mechanical classifications together. ISEA’s public labeling guidance and the ANSI Blog both describe a pentagon pictogram:
- Cut at the top center
- Abrasion on the left
- Puncture on the right
ISEA’s labeling guidance also states that an X may be used in place of a rating to show that the classification was not tested or is not applicable. A badge with an X in one position is incomplete information if the RFQ simply copies the other two numbers and ignores the X.
The ANSI Blog’s overview of 2024 changes also records that the scope now covers sleeves as well as gloves; that the edition includes language on demonstrating conformity to claimed classifications, referencing ANSI/ISEA 125-2021; and that abrasion and conductive-heat classification language was clarified. Buyers should ask for the 2024 text when that is the edition they mean. A website or datasheet that only says “ANSI 105” does not tell you which edition, which property, or which part of the glove was classified.
The ANSI Blog further states that where the material in the glove varies, testing of the intended resistance area should be performed, and end users should be notified about varying performance levels. A palm classification is not automatically a 360-degree classification. Do not assume the back of the hand, the cuff, or a lighter coating shares the number printed for the palm.
Puncture and abrasion are separate classifications
ISEA’s public fact sheet treats mechanical protection as more than cut:
- Puncture resistance is assessed by the force required to puncture the material with a sharp probe.
- Abrasion resistance is measured by the number of abrasion cycles the material can withstand before failure.
The ANSI Blog also lists hypodermic needle puncture resistance as a distinct mechanical classification, separate from ordinary puncture. That distinction matters because EN 388 puncture testing, in SATRA’s public overview, uses a rounded stylus and is not a hypodermic-needle test. If your tender actually needs needle-puncture performance, say so. Do not treat an EN 388 puncture number, or an ANSI ordinary-puncture class, as a needle-puncture result.
Chemical permeation, chemical degradation, and heat or flame classifications are likewise separate conversations. A high cut class does not answer a chemical-splash question. For chemical-protection pathways more broadly, see chemical resistant gloves.
ANSI cut classes are not interchangeable with EN 388
This is the point most dual-market RFQs under-specify.
EN 388 reports mechanical-risk performance in a European marking system. Its straight-blade cut result, when reported, uses ISO 13997 and letter levels A to F, with the result in newtons. ANSI/ISEA 105-2024 reports cut classification on an A1–A9 scale in grams-force, and ISEA names ASTM F2992-23 as the cut test method.
The two conversations may look similar—both talk about a straight blade and a 20 mm cut distance—but they are not the same named method, they do not use the same unit or the same number of published classes, and public ISEA and ANSI pages do not authorize a simple conversion table in a brochure. A glove marked EN 388 “F” is not automatically ANSI “A6,” and an ANSI “A7,” “A8,” or “A9” class is not automatically “beyond F” unless the current test reports for that SKU say so.
If a tender needs both a North American classification and a European PPE marking, ask for both, plus the test methods, the edition dates, and the user information. Do not translate a letter into a number to win the comparison.
Why a cut level alone is not an RFQ
A string such as “A4” or “ANSI 105” does not tell you:
- which edition is being claimed (including whether the 2024 pentagon marking applies);
- whether cut was tested to ASTM F2992-23, or some older or informal method;
- whether abrasion or puncture was tested, or marked X;
- whether hypodermic-needle puncture, chemical, or heat classifications are needed and missing;
- which part of the glove was tested;
- whether the offer is PPE, medical, or another regulatory frame;
- whether the marking on the shipped SKU matches the datasheet.
Ask the buyer—or rewrite the RFQ—to name the actual hazard, the destination market, the edition of ANSI/ISEA 105 that is required, any EN 388 or EN ISO 21420 evidence also required, and the files that belong to the exact SKU.
RFQ checklist for ANSI/ISEA 105-style conversations
- Destination market — United States, Canada, a multi-country program, or another named market, and whether European PPE rules also apply.
- Actual workplace hazards — cut, abrasion, puncture, needle puncture, chemical, heat, or a combination; plus hazards this standard does not cover, such as welding or electrical shock.
- Regulatory frame — occupational PPE, medical, food contact, or a combination that must be documented separately.
- Edition — ANSI/ISEA 105-2024, or the edition the destination actually uses; do not leave only “ANSI 105.”
- Which properties are being classified — cut, abrasion, puncture, hypodermic-needle puncture, chemical, or heat, and where an X is acceptable.
- Test method named for cut — ASTM F2992-23 if that is the 2024 cut method being claimed.
- Which part of the glove or sleeve was tested, and whether performance varies by area.
- If EN 388 is also required — report it separately; do not convert classes. See EN 388 protective gloves.
- Product construction — polymer, coating, liner, cuff, and whether the item is reusable protective wear or a disposable product being asked to do mechanical-risk work.
- Destination documentation confirmed by product and market — see /quality; do not invent certificate numbers.
- Lot / batch evidence for the shipped lots, as agreed in the purchase terms.
Buying terms, lead time, and sample logistics are on /buying. Use that page rather than repeating commercial figures in every article.
Frequently asked questions
Q1. Can I convert an ANSI cut class into an EN 388 letter? Not with a brochure shortcut. ISEA names ASTM F2992-23 for the 2024 cut classification; EN 388 uses a different European marking system, including ISO 13997 letter levels when the straight-blade result is reported. Ask for both sets of results when both markets matter.
Q2. Does a higher cut class always mean a safer glove? No. A classification describes tested performance for a named property, usually on a defined area of the product. It does not automatically improve grip, chemical resistance, or heat protection, and it does not make the glove cut-proof.
Q3. If the pentagon shows a cut class, do abrasion and puncture match it? Not necessarily. Each property is classified separately. ISEA’s labeling guidance also allows an X when a classification was not tested or is not applicable.
Q4. Is ANSI/ISEA 105 an OSHA or CE certificate? No. ISEA describes the standard as voluntary. OSHA’s public hand-protection rule is a separate employer duty. A cut class is also not a European CE mark. See EN 388 protective gloves and EN ISO 21420 protective gloves for the European mechanical-risk and general-requirements conversations.
Q5. Does this article claim that JUNDA protective gloves are ANSI/ISEA 105 classified or carry a particular A1–A9 rating? It does not. Guangzhou Junda Gloves Co., Ltd. (JUNDA) manufactures disposable programs under brands such as GYMDA, as well as latex protective programs under series such as Yue Long and Baijiebang, and supports OEM / private-label discussions. Production bases include Guangzhou and Shaoguan (GYMDA is the Shaoguan disposable production base). Whether a given model has PPE files, which standards are in scope, and how markings and user information are worded must be confirmed against the product under discussion and the current files—by product and market.
Q6. Where should buyers start on the JUNDA website? Start from long-cuff latex protective gloves, household flock-lined latex gloves, /oem, /quality, and /buying. Ask for evidence that belongs to the exact offer, not a generic “ANSI A4” or “cut level 5” slogan.
Next step for buyers
When you write a North American or dual-market protective-glove tender, keep four things separate: the actual hazard (cut, abrasion, puncture, chemical, heat), the classification edition you mean (ANSI/ISEA 105-2024, or another named edition), any European PPE marking you also need, and the files that belong to the exact SKU. Then ask what was tested, on which part of the glove, and how the shipped product will be marked.
To discuss a protective or disposable glove program for a named destination market, email sales@jundagloves.com or contact JUNDA through the WhatsApp button on the website. Please include the destination market, the expected mechanical or other hazards, construction, size range, and documentation requirements, so the discussion stays on current markings, user information, and files rather than a brochure line that only says “ANSI/ISEA 105.”